Development and production
of electronic equipment
RU EN

УКПБ.02, УКПБ.04

Battery parameter monitoring device. ВПТС.426471.200-02, ВПТС.426471.200-04
M25 IP20 CAN Wi-Fi GSM

Purpose

Battery (SB) parameters monitoring and writing to the non-volatile memory:

  • Battery charge/discharge current (A).
  • Battery voltage (V).
  • Battery charge level (Ah).
  • Ambient temperature (°C).

Wi-Fi, CAN, GSM data transmission.

Application

  • Subway cars.
  • Electric train cars.

Key features

  • Battery voltage, temperature and current registration.
  • Current battery charge calculation.
  • Received information analysis.
  • Driver and depot personnel prompts regarding the necessary actions to maintain the battery in good condition.
  • Integration into the general train diagnostic system.
  • Increasing battery service life.
  • Control of the power source of the battery charge circuit to form the optimal battery charge profile depending on the battery condition, discharge level and ambient temperature.
  • Ability to record digital signals.
  • The solution has been developed on the rolling stock of Russian Railways.
  • УКПБ device installation:
    • In the undercar box, directly on the battery.
    • The УКПБ fastening and current sensor location are adapted to specific conditions.
    • It can be performed in a depot during maintenance or factory repair.

Specifications

Unit power supply parameters

Version Supply voltage (DC), V The voltage measurement stage
is connected to the unit supply voltage
Version -00 Supply voltage (DC), V 50-90 The voltage measurement stage
is connected to the unit supply voltage
✓
Version -01 Supply voltage (DC), V 50-90 The voltage measurement stage
is connected to the unit supply voltage
✓
Version -02 Supply voltage (DC), V 50-140 The voltage measurement stage
is connected to the unit supply voltage
✓
Version -03 Supply voltage (DC), V 50-90 The voltage measurement stage
is connected to the unit supply voltage
✗
Version -04 Supply voltage (DC), V 11-32 The voltage measurement stage
is connected to the unit supply voltage
✓
Version -05 Supply voltage (DC), V 50-140 The voltage measurement stage
is connected to the unit supply voltage
✓

Average power consumption in sleep mode (storage mode as part of the battery until commissioning on the rolling stock)

Version Average power consumption in sleep mode, W
Version -00 Average power consumption in sleep mode, W 6 max
Version -01, -02, -03, -04, -05 Average power consumption in sleep mode, W 0.8 max

Voltage measurement ranges

Version Voltage measurement range, V Accuracy, V
Version -00, -01 Voltage measurement range, V 0-105 Accuracy, V ±0,5
Version -02 Voltage measurement range, V 0-150 Accuracy, V ±0,7
Version -03 Voltage measurement range, V 0-300 Accuracy, V ±0,7
Version -04 Voltage measurement range, V 0-50 Accuracy, V ±0,25
Version -05 Voltage measurement range, V 0-150 Accuracy, V ±0,7

Current measurement ranges

Version Current measurement range, A Accuracy, A
Version -00 Current measurement range, A -72..+72 Accuracy, A ±0,5
Version -01 Current measurement range, A -100..+100 Accuracy, A ±0,5
Version -02 Current measurement range, A -120..+120 Accuracy, A ±1
Version -03 Current measurement range, A -100..+100 Accuracy, A ±0,5
Version -04 Current measurement range, A -1500..+1500 Accuracy, A ±7,5
Version -05 Current measurement range, A -100..+100 Accuracy, A ±0,5

Temperature measurement range: from minus 50 °C to plus 60 °C, measurement accuracy ±1 °C.
The unit weight is 1.2 kg max.

Product catalog
Product catalog
Download