The controller is designed to control the operation of external automatic doors on locomotive traction passenger cars manufactured by JSC TVZ. Subsystem of the rolling stock elements safety control.
The signals from the door electrical equipment and the door control unit are fed to the УКПБ control unit. A non-contact sensor reads the motor current. The voltage measurement channel is used to monitor the train power supply network.
Data is written to the non-volatile memory on the following events:
In the case of a report of abnormal door operation it is possible to read the data of the УКПБ via wireless interface CAN, Wi-Fi for subsequent deciphering and determination of the causes and consequences of errors in the door control unit operation.
Device parameter | Value |
---|---|
Min. supply voltage (DC) | 50 V |
Max. supply voltage (DC) | 144 V |
Measuring current channel range | ±120 А |
Current channel accuracy | ±1 А* |
Voltage measuring channel range | 0..150 V |
Accuracy of the voltage measurement channel | ±0,7 V |
Temperature measuring channel range | -50..+60 °C |
Temperature measuring channel accuracy | ±1,5 °C |
Number of digital inputs | 32 |
*At the upper limit of the measuring range